Make : COLEMAN | Model : TARA | Year : 1985 |
Build Dates : 19850401 - 19850501 | ||
NHTSA Campaign ID Number : 85V100000 | ||
Date Owners Notified: 19850806 | Date Received by ODI: 19850806 | Date Added to Database: 19850814 |
Manufacturer(s) Involved: COLEMAN CO., INC. | ||
Manufacturer(s) Responsible for the Recall: FLEETWOOD FOLDING TRAILER, INC. | ||
Manufacturer Campaign Number: | ||
Component: ELECTRICAL SYSTEM:WIRING | ||
Potential Number of Units Affected: 1168 | ||
Summary of the Safety Concern:
THE DEFECT INVOLVES THE 115 VAC ROMEX WIRE ROUTED INSIDE THE REAR BODY PANEL AND ACROSS THE SPARE TIRE MOUNTING BRACKET. THIS WIRE MAY SLIP AND BE PINCHED BETWEEN THE SPARE TIRE MOUNTING BOLT AND THE BULKHEAD. IF THE INSULATION IS DAMAGED AND IF THE 120 VOLT AC LINE (CORD) IS PLUGGED IN, THE TRAILER WOULD BE AT A 120 VOLT AC POTENTIAL (HOT). CONSEQUENCE OF DEFECT: IF THE TRAILER IS AT 120 VOLT AC POTENTIAL, A PERSON MAY BE SHOCKED, BURNED OR ELECTROCUTED. |
||
Consequence:
|
||
Remedy:
INSPECTING AND MODIFYING WIRING IN SUCH A FASHION AS TO PRECLUDE ANY POTENTIAL SLIPPAGE OF WIRING INTO THE PATH OF THE SPARE TIRE MOUNTING BRACKET ASSEMBLY. |
||
Report Initiator: ODI | Vehicles Report | |
Regulation Part Number: | Federal Motor Vehicle Safety Standard Number: | |
Notes:
CUSTOMERS CAN ALSO CONTACT THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION S AUTO SAFETY HOTLINE AT 1-888-DASH-2-DOT (1-888-327-4236). |