Make : NEOPLAN | Model : AN440 TRANSLINER | Year : 2005 |
Build Dates : 20040601 - 20050331 | ||
NHTSA Campaign ID Number : 05V321000 | ||
Date Owners Notified: | Date Received by ODI: 20050714 | Date Added to Database: 20050714 |
Manufacturer(s) Involved: NEOPLAN USA CORPORATION | ||
Manufacturer(s) Responsible for the Recall: NEOPLAN USA CORPORATION | ||
Manufacturer Campaign Number: | ||
Component: STRUCTURE:BODY:DOOR | ||
Potential Number of Units Affected: 311 | ||
Summary of the Safety Concern:
ON CERTAIN TRANSIT BUSES EQUIPPED WITH VAPOR DOOR ASSEMBLIES, THE TWO PIECE CURVED CONNECTING RODS WHEN USED AS AN ELEMENT OF THE DOOR ACTUATION LINKAGE IN CONJUNCTION WITH A VAPOR MEDIUM PNEUMATIC DIFFERENTIAL ENGINE, MAY BE SUBJECT TO FATIGUE FAILURE RESULTING IN BENDING OR BREAKING OF THE CONNECTING ROD. |
||
Consequence:
A BROKEN CONNECTING ROD CAN ALLOW THE DOOR PANEL TO MOVE FREELY IN AN UNCONTROLLED MANNER, LEAVING PASSENGERS INSIDE THE VEHICLE UNPROTECTED BY THE DOOR PANEL AND ENABLING A PROTRUDING DOOR PANEL TO STRIKE PERSONS OR OBJECTS OUTSIDE THE VEHICLE. |
||
Remedy:
NEOPLAN IS WORKING WITH VAPOR BUS INTERNATIONAL TO NOTIFY OWNERS AND HAVE THE REPAIR PERFORMED ON THEIR VEHICLES. THE REMEDY CONSISTS OF REPLACING THE TWO PIECE CONNECTING ROD WITH A ONE PIECE CONNECTING ROD. OWNERS SHOULD CONTACT VAPOR AT 1-847-777-6400 OR NEOPLAN AT 1-719-336-3256. |
||
Report Initiator: ODI | Vehicles Report | |
Regulation Part Number: | Federal Motor Vehicle Safety Standard Number: | |
Notes:
CUSTOMERS CAN ALSO CONTACT THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION S AUTO SAFETY HOTLINE AT 1-888-DASH-2-DOT (1-888-327-4236). |